← Kompas Titration & Gravimetry Lab SPM → degree
Titration & gravimetry

Count it, or weigh it.

Two flasks look identical; one holds twice the chloride. Measure the difference by the reagent it takes to react (titration), or by the mass of solid it becomes (gravimetry).

Count it or weigh it
Basics · 1/2

Every method asks the same four questions.

1 · What reacts?

Analyte + reagent, in a fixed ratio.

2 · Why does it finish?

It goes almost fully to products: the equilibrium constant, K, is very large.

3 · How do we see the end?

A visible signal: a colour, a solid, or no more cloudiness.

4 · How does it become a number?

Ratio × amount of reagent used, or mass of solid formed.

1Fast2Complete3Known ratio4Visible end
Basics · 2/2

Equivalence vs end point.

Equivalence: reagent exactly matches analyte. End point: where we see it. The gap is titration error; a good indicator keeps it under one drop.

Particle counter
01 · Acid–base · 1/2

An acid hands H⁺ to a base. Count the base it takes.

1 · What reacts?

H⁺ + OH⁻ → H₂O. A weak acid works too: HA + OH⁻ → A⁻ + H₂O.

2 · Why does it finish?

Water barely splits back (K ≈ 10¹⁴ for H⁺ + OH⁻).

3 · How do we see the end?

The indicator is a weak acid. HIn and In⁻ differ in colour; it flips over ~2 pH units.

4 · How does it become a number?

Mole ratio from the equation × C × V of titrant.

Pharmacy: non-aqueous perchloric acid titration is the standard pharmacopoeial assay for many weak-base drugs.

01 · Acid–base · 2/2

Pick the indicator for the equivalence pH.

Watch outNot pH 7. Weak acid + strong base ends above 7, so use phenolphthalein (8.2–10.0), not methyl orange (3.1–4.4).
Acid–Base Lab Full titration curve and the molecules at equivalence Open →
Indicator flip
simplified shape
02 · Precipitation · 1/4

Silver grabs chloride and drops out as a solid. Count the silver.

1 · What reacts?

Ag⁺ + Cl⁻ → AgCl(s), 1 : 1.

2 · Why does it finish?

AgCl barely dissolves (Ksp ≈ 1.8 × 10⁻¹⁰): almost no Cl⁻ is left.

3 · How do we see the end?

Three ways: Mohr, Volhard, Fajans.

4 · How does it become a number?

mol Cl⁻ = mol Ag⁺ used.

Pharmacy: chloride content of sodium chloride and potassium chloride preparations.

02 · Precipitation · 2/4

Three ways to see the end.

Mohr

Ag⁺ direct. Chromate turns red-brown (Ag₂CrO₄). Needs pH ≈ 6.5–10.

titrant
Ag⁺, direct
indicator
Chromate, CrO₄²⁻
you see
Red-brown Ag₂CrO₄
needs
pH ≈ 6.5–10

Volhard

Excess Ag⁺, back-titrated with SCN⁻. Fe³⁺ turns red. Needs acid (HNO₃).

titrant
Excess Ag⁺, back with SCN⁻
indicator
Fe³⁺
you see
Red Fe(SCN)²⁺
needs
Acid (HNO₃)

Fajans

Ag⁺ direct. A dye turns the solid's surface pink. Needs colloidal AgCl.

titrant
Ag⁺, direct
indicator
Adsorption dye
you see
Pink solid surface
needs
Colloidal AgCl
Watch outMohr at the wrong pH fails. Too acidic: chromate becomes dichromate and no red forms. Too alkaline: silver oxide forms and the end point blurs.
02 · Precipitation · 3/4

Mohr: who precipitates first.

AgCl needs far less Ag⁺ to form than Ag₂CrO₄ does, so chromate waits until the chloride is gone.

Mohr
02 · Precipitation · 4/4

Fajans: the surface flips.

The dye never reacts. It sticks to the solid once the surface turns positive.

Fajans · one AgCl particle, magnified
03 · Redox · 1/3

One gives electrons, the other takes them. Count the electrons.

1 · What reacts?

MnO₄⁻ + 5Fe²⁺ + 8H⁺ → Mn²⁺ + 5Fe³⁺ + 4H₂O

2 · Why does it finish?

A big potential gap: MnO₄⁻/Mn²⁺ +1.51 V vs Fe³⁺/Fe²⁺ +0.77 V.

3 · How do we see the end?

Permanganate is its own indicator: purple persists once the analyte runs out. Iodine: starch turns blue-black.

4 · How does it become a number?

Balance electrons first: MnO₄⁻ takes 5, Fe²⁺ gives 1, so 1 : 5.

03 · Redox · 2/3

The titrant is the indicator.

Watch outAcidify permanganate with sulfuric acid, not hydrochloric. It oxidises Cl⁻ to chlorine, uses extra titrant, and the result reads high.
Electron hop
03 · Redox · 3/3

Iodine, two ways.

Iodimetry · direct

Standard I₂ oxidises the analyte. Example: ascorbic acid.

happens
I₂ oxidises the analyte
titrant
Standard I₂
example
Ascorbic acid

Iodometry · indirect

The analyte frees I₂ from excess I⁻; titrate that I₂ with thiosulfate. Example: oxidants (Cu²⁺, peroxides).

happens
Analyte oxidises excess I⁻ to I₂; titrate the I₂ released
titrant
Thiosulfate, S₂O₃²⁻
example
Oxidants (Cu²⁺, peroxides)

Pharmacy: hydrogen peroxide solution by permanganate; ascorbic acid by iodine; ferrous salts by cerium(IV).

04 · Complexometric · 1/2

EDTA wraps a metal ion like a claw. Count the claws.

1 · What reacts?

M²⁺ + EDTA⁴⁻ → [M–EDTA]²⁻. Always 1 : 1.

2 · Why does it finish?

Six arms grip at once: very stable (log Kf ≈ 10.7 for Ca²⁺).

3 · How do we see the end?

Eriochrome Black T is wine-red holding the metal, blue when free.

4 · How does it become a number?

mol metal = mol EDTA. The simplest ratio here.

Pharmacy: calcium salts (e.g. calcium gluconate), zinc salts, and Al/Mg in antacids.

04 · Complexometric · 2/2

The end point is a steal.

The indicator must hold the metal more weakly than EDTA does, or it never lets go.

Watch outBuffer at pH 10 (ammonia) for Ca²⁺/Mg²⁺. Too acidic: H⁺ blocks EDTA. Too alkaline: the metal precipitates as hydroxide.
The steal · EDTA drawn as a claw
05 · Gravimetric · 1/3

Make a pure solid of known formula. Weigh it.

1 · What reacts?

Ba²⁺ + SO₄²⁻ → BaSO₄(s)

2 · Why does it finish?

BaSO₄ barely dissolves (Ksp ≈ 1.1 × 10⁻¹⁰); excess Ba²⁺ pushes it further.

3 · How do we see the end?

Add a drop more reagent to the clear liquid. No new cloudiness: complete.

4 · How does it become a number?

Mass of solid × gravimetric factor = mass of analyte.

05 · Gravimetric · 2/3

From cloud to crucible.

A good precipitate is very insoluble, pure, of known formula, with crystals big enough to filter.

Watch outWeigh only at constant mass. A wet precipitate weighs too much and the result reads high.

Pharmacy: loss on drying, sulfated ash and residue on ignition are gravimetric tests.

From cloud to crucible
05 · Gravimetric · 3/3

What goes wrong: occlusion.

A crystal that grows too fast traps stray ions. Washing can't reach them, so the mass reads high. Slow, hot, dilute precipitation and digestion prevent it.

Occlusion
Try it

Which method would you use?

Pick a method, then how you'd see the end. Wrong picks tell you why. Nothing is saved.

Summary

Five methods, one frame.